Design optimization of a submersible chemiluminescent sensor (DISCO) for improved quantification of reactive oxygen species (ROS) in surface waters
Design optimization of a submersible chemiluminescent sensor (DISCO) for improved quantification of reactive oxygen species (ROS) in surface waters
Date
2022-09-03
Authors
Grabb, Kalina C.
Pardis, William A.
Kapit, Jason
Wankel, Scott D.
Hayden, Eric B.
Hansel, Colleen M.
Pardis, William A.
Kapit, Jason
Wankel, Scott D.
Hayden, Eric B.
Hansel, Colleen M.
Linked Authors
Person
Person
Person
Person
Person
Alternative Title
Citable URI
As Published
Date Created
Location
DOI
10.3390/s22176683
Related Materials
Replaces
Replaced By
Keywords
Reactive oxygen species
Superoxide
Chemiluminescent
In situ analysis
Ocean sensor
Corals
Superoxide
Chemiluminescent
In situ analysis
Ocean sensor
Corals
Abstract
Reactive oxygen species (ROS) are key drivers of biogeochemical cycling while also exhibiting both positive and negative effects on marine ecosystem health. However, quantification of the ROS superoxide (O2−) within environmental systems is hindered by its short half-life. Recently, the development of the diver-operated submersible chemiluminescent sensor (DISCO), a submersible, handheld instrument, enabled in situ superoxide measurements in real time within shallow coral reef ecosystems. Here, we present a redesigned and improved instrument, DISCO II. Similar to the previous DISCO, DISCO II is a self-contained, submersible sensor, deployable to 30 m depth and capable of measuring reactive intermediate species in real time. DISCO II is smaller, lighter, lower cost, and more robust than its predecessor. Laboratory validation of DISCO II demonstrated an average limit of detection in natural seawater of 133.1 pM and a percent variance of 0.7%, with stable photo multiplier tube (PMT) counts, internal temperature, and flow rates. DISCO II can also be optimized for diverse environmental conditions by adjustment of the PMT supply voltage and integration time. Field tests showed no drift in the data with a percent variance of 3.0%. Wand tip adaptations allow for in situ calibrations and decay rates of superoxide using a chemical source of superoxide (SOTS-1). Overall, DISCO II is a versatile, user-friendly sensor that enables measurements in diverse environments, thereby improving our understanding of the cycling of reactive intermediates, such as ROS, across various marine ecosystems.
Description
© The Author(s), 2022. This article is distributed under the terms of the Creative Commons Attribution License. The definitive version was published in Grabb, K., Pardis, W., Kapit, J., Wankel, S., Hayden, E., & Hansel, C. Design optimization of a submersible chemiluminescent sensor (DISCO) for improved quantification of reactive oxygen species (ROS) in surface waters. Sensors, 22(17), (2022): 6683, https://doi.org/10.3390/s22176683.