C-14 Blank Corrections for 25-100 mu G samples at the National Ocean Sciences AMS Laboratory

Thumbnail Image
Date
2019-07-22
Authors
Roberts, Mark L.
Elder, Kathryn L.
Jenkins, William J.
Gagnon, Alan R.
Xu, Li
Hlavenka, Joshua
Longworth, Brett E.
Alternative Title
Date Created
Location
DOI
10.1017/RDC.2019.74
Related Materials
Replaces
Replaced By
Keywords
AMS
AMS dating
Blank corrections
Abstract
Replicate radiocarbon (14C) measurements of organic and inorganic control samples, with known Fraction Modern values in the range Fm = 0–1.5 and mass range 6 μg–2 mg carbon, are used to determine both the mass and radiocarbon content of the blank carbon introduced during sample processing and measurement in our laboratory. These data are used to model, separately for organic and inorganic samples, the blank contribution and subsequently “blank correct” measured unknowns in the mass range 25–100 μg. Data, formulas, and an assessment of the precision and accuracy of the blank correction are presented.
Description
© The Author(s), 2019. This article is distributed under the terms of the Creative Commons Attribution License. The definitive version was published in Roberts, Mark L., Elder, Kathryn L., Jenkins, William J., Gagnon, Alan R., Xu, Li, Hlavenka, Joshua D., & Longworth, Brett E. C-14 Blank Corrections for 25-100 mu G samples at the National Ocean Sciences AMS Laboratory. Radiocarbon, 61(5), (2019): 1403-1411, Doi: 10.1017/RDC.2019.74.
Embargo Date
Citation
Roberts, Mark L., Elder, Kathryn L., Jenkins, William J., Gagnon, Alan R., Xu, Li, Hlavenka, Joshua D., & Longworth, Brett E. (2019). C-14 Blank Corrections for 25-100 mu G samples at the National Ocean Sciences AMS Laboratory. Radiocarbon, 61(5), 1403-1411.
Cruises
Cruise ID
Cruise DOI
Vessel Name
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-ShareAlike 4.0 International