A robust calibration method for continental-scale soil water content measurements

Thumbnail Image
Date
2018-05-24
Authors
Roberti, Joshua A.
Ayres, Edward
Loescher, Henry W.
Tang, Jianwu
Starr, Gregory
Durden, David J.
Smith, Derek E.
de la Reguera, Elizabeth
Morkeski, Kate
McKlveen, Margot
Benstead, Heidi
SanClements, Michael D.
Lee, Robert H.
Gebremedhin, Gebremedhin
Zulueta, Rommel C.
Alternative Title
Date Created
Location
DOI
10.2136/vzj2017.10.0177
Related Materials
Replaces
Replaced By
Keywords
Abstract
Technological advances have allowed in situ monitoring of soil water content in an automated manner. These advances, along with an increase in large-scale networks monitoring soil water content, stress the need for a robust calibration framework that ensures that soil water content measurements are accurate and reliable. We have developed an approach to make consistent and comparable soil water content sensor calibrations across a continental-scale network in a production framework that incorporates a thorough accounting of uncertainties. More than 150 soil blocks of varying characteristics from 33 locations across the United States were used to generate soil-specific calibration coefficients for a capacitance sensor. We found that the manufacturer’s nominal calibration coefficients poorly fit the data for nearly all soil types. This resulted in negative (91% of samples) and positive (5% of samples) biases and a mean root mean square error (RMSE) of 0.123 cm3 cm−3 (1σ) relative to reference standard measurements. We derived soil-specific coefficients, and when used with the manufacturer’s nominal function, the biases were corrected and the mean RMSE dropped to ±0.017 cm3 cm−3 (±1σ). A logistic calibration function further reduced the mean RMSE to ±0.016 cm3 cm−3 (±1σ) and increased the range of soil moistures to which the calibration applied by 18% compared with the manufacturer’s function. However, the uncertainty of the reference standard was notable (±0.022 cm3 cm−3), and when propagated in quadrature with RMSE estimates, the combined uncertainty of the calibrated volumetric soil water content values increased to ±0.028 cm3 cm−3 regardless of the calibration function used.
Description
© Soil Science Society of America, 2018. This article is distributed under the terms of the Creative Commons Attribution License. The definitive version was published in Vadose Zone Journal 17 (2018): 170177, doi:10.2136/vzj2017.10.0177.
Embargo Date
Citation
Vadose Zone Journal 17 (2018): 170177