Cs feed tests and emittance measurements on a modified MC-SNICS ion source for radiocarbon AMS

dc.contributor.author Southon, John R.
dc.contributor.author Santos, Guaciara M.
dc.contributor.author Han, Baoxi
dc.date.accessioned 2011-03-09T20:23:54Z
dc.date.available 2011-03-09T20:23:54Z
dc.date.issued 2007-11
dc.description Author Posting. © Arizona Board of Regents on behalf of the University of Arizona, 2007. This article is posted here by permission of Dept. of Geosciences, University of Arizona for personal use, not for redistribution. The definitive version was published in Radiocarbon 49 (2007): 301-306. en_US
dc.description.abstract We report on 2 recent developments in an ongoing program of characterizing and improving the National Electrostatics Corp. (NEC) MC-SNICS ion source at University of California (UC) Irvine’s Keck AMS laboratory. First, we have investigated the possibility of modifying a large-body (134-sample) MC-SNICS to incorporate the UC Irvine Cs oven and vacuum-insulated Cs feed tube, which provide better confinement of Cs than the standard NEC setup. In our 40-sample source, the feed tube enters the source housing directly below the ionizer assembly. This area cannot be accessed for machining on the 134-sample source, but we have successfully tested a modified geometry where the delivery tube enters the body via the source end flange. Second, we recently installed a second beam profile monitor in the injection line of our spectrometer to allow us to make online emittance measurements. At full output (150 μA of C– at 55 keV), the emittance of our source at 8 kV sputtering voltage is approximately 40π mm mrad. en_US
dc.format.mimetype application/pdf
dc.identifier.citation Radiocarbon 49 (2007): 301-306 en_US
dc.identifier.uri https://hdl.handle.net/1912/4389
dc.language.iso en_US en_US
dc.publisher Dept. of Geosciences, University of Arizona en_US
dc.relation.uri https://journals.uair.arizona.edu/index.php/radiocarbon/article/view/2929
dc.title Cs feed tests and emittance measurements on a modified MC-SNICS ion source for radiocarbon AMS en_US
dc.type Article en_US
dspace.entity.type Publication
relation.isAuthorOfPublication 8a50303a-a15e-4273-a406-390eb2123a32
relation.isAuthorOfPublication 7bceada8-ac66-496e-aa61-2dd74a848ff7
relation.isAuthorOfPublication e9815764-5164-4a3a-88a1-25452fbfc1d1
relation.isAuthorOfPublication.latestForDiscovery 8a50303a-a15e-4273-a406-390eb2123a32
Files
Original bundle
Now showing 1 - 1 of 1
Thumbnail Image
Name:
_301-306.pdf
Size:
2.91 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.89 KB
Format:
Item-specific license agreed upon to submission
Description: