Schultz Adam

No Thumbnail Available
Last Name
Schultz
First Name
Adam
ORCID

Search Results

Now showing 1 - 2 of 2
  • Technical Report
    Report of a workshop on technical approaches to construction of a seafloor geomagnetic observatory
    (Woods Hole Oceanographic Institution, 1995-09) Chave, Alan D. ; Green, Arthur W. ; Filloux, Jean H. ; Law, Lawrie K. ; Petitt, Robert A. ; Rasson, Jean L. ; Schultz, Adam ; Spiess, Fred N. ; Tarits, Pascal ; Tivey, Maurice A. ; Webb, Spahr C.
    This report considers the technical issues on sensors, data recording and transmission, control and timing, power, and packaging associated with constricting a seafloor geomagnetic observatory. Existing technologies either already in use for oceanographic purposes or adapted from terrestral geomagnetic observatories could be applied to measure the vector magnetic field components and absolute intensity with minimal development. The major technical challenge arises in measuring absolute direction on the seafloor because terrestral techniques are not transferrable to the deep ocean. Two solutions to this problem were identified. The first requires the development of an instrument which measures the instantaneous declination and inclination of the magnetic field relative to a north-seeking gyroscope and the local vertical. The second is a straightforward extension of a precision acoustic method for determining absolute position on the seafloor.
  • Article
    Estimate of heat flux and its temporal variation at the TAG hydrothermal mound, Mid-Atlantic Ridge 26°N
    (American Geophysical Union, 2003-09-17) Goto, Shusaku ; Kinoshita, Masataka ; Schultz, Adam ; von Herzen, Richard P.
    From August 1994 to March 1995, three 50-m-high vertical thermistor arrays designated “Giant Kelps” (GKs) were deployed around the central black smoker complex (CBC) at the TAG hydrothermal mound, Mid-Atlantic Ridge (26°08primeN, 44°49primeW). These were designed to monitor the temporal variability of the vertical temperature distribution in the hydrothermal plume. One small high-temperature probe “Hobo” was also deployed in one of the black smoker vents of CBC. Over the observation period, two typical characteristics are recognized in plume temperatures measured with GKs: (1) the amplitudes of temperature anomalies decrease with increasing height above the top of CBC; (2) maximum temperature anomalies on the upper thermistors occurred periodically and nearly simultaneously across the array about every 6 hours. Conversely, maximum temperature anomalies on the lower thermistors occurred periodically every 12 hours, indicating that the location of the plume discharged from CBC was forcibly moved by the change in direction of tidally modulated current flow. The heat flux from CBC was estimated from temperatures measured by GKs based on a model of buoyant hydrothermal fluid rising in a stable, stratified density environment. The estimated heat flux from CBC gradually decreases from about 86 to 55 MW over the ~7 months of measurement, with a mean rate of decrease of 0.17 MW d-1. Since the black smoker effluent temperature measured with Hobo was almost stable over the measurement period, a plausible cause of the decrease is a reduction in the volume of hydrothermal fluid provided to the CBC (in which case the estimated mean rate of decrease in volume flux of CBC is 8.9 m3 d-1). Estimated heat flux, temperature anomalies observed by Hobo, and diffuse flow and subbottom temperature anomalies recorded by other long-term monitoring instruments before, during, and after ODP Leg 158 indicate that the drilling probably affected the fluid flow pattern within the mound but had little effect on the total heat flux from CBC.