Kinoshita
Masataka
Kinoshita
Masataka
No Thumbnail Available
Search Results
Now showing
1 - 2 of 2
-
ArticleSubmersible study of an oceanic megamullion in the central North Atlantic(American Geophysical Union, 2001-08-10) Tucholke, Brian E. ; Fujioka, Kantaro ; Ishihara, Takemi ; Hirth, Greg ; Kinoshita, MasatakaRecently discovered megamullions on the seafloor have been interpreted to be the exhumed footwalls of long-lived detachment faults operating near the ends of spreading segments in slow spreading crust. We conducted five submersible dives on one of these features just east of the rift valley in the Mid-Atlantic Ridge at 26°35′N and obtained visual, rock sample, gravity, and heat flow data along a transect from the breakaway zone (where the fault is interpreted to have first nucleated in ∼2.0–2.2 Ma crust) westward to near the termination (∼0.7 Ma). Our observations are consistent with the detachment fault hypothesis and show the following features. In the breakaway zone, faulted and steeply backtilted basaltic blocks suggest rotation above a deeper shear zone; the youngest normal faults in this sequence are interpreted to have evolved into the long-lived detachment fault. In younger crust the interpreted detachment surface rises as monotonously flat seafloor in a pair of broad, gently sloping domes that formed simultaneously along isochrons and are now thinly covered by sediment. The detachment surface is locally littered with basaltic debris that may have been clipped from the hanging wall. The domes coincide with a gravity high that continues along isochrons within the spreading segment. Modeling of on-bottom gravity measurements and recovery of serpentinites imply that mantle rises steeply and is exposed within ∼7 km west of the breakaway but that rocks with intermediate densities prevail farther west. Within ∼5 km of the termination, small volcanic cones appear on the detachment surface, indicating melt input into the footwall. We interpret the megamullion to have developed during a phase of limited magmatism in the spreading segment, with mantle being exhumed by the detachment fault <0.5 m.y. after its initiation. Increasing magmatism may eventually have weakened the lithosphere and facilitated propagation of a rift that terminated slip on the detachment fault progressively between ∼1.3 m.y. and 0.7 m.y. Identifiable but low-amplitude magnetic anomalies over the megamullion indicate that it incorporates a magmatic component. We infer that much of the footwall is composed of variably serpentinized peridotite intruded by plutons and dikes.
-
ArticleEstimate of heat flux and its temporal variation at the TAG hydrothermal mound, Mid-Atlantic Ridge 26°N(American Geophysical Union, 2003-09-17) Goto, Shusaku ; Kinoshita, Masataka ; Schultz, Adam ; von Herzen, Richard P.From August 1994 to March 1995, three 50-m-high vertical thermistor arrays designated “Giant Kelps” (GKs) were deployed around the central black smoker complex (CBC) at the TAG hydrothermal mound, Mid-Atlantic Ridge (26°08primeN, 44°49primeW). These were designed to monitor the temporal variability of the vertical temperature distribution in the hydrothermal plume. One small high-temperature probe “Hobo” was also deployed in one of the black smoker vents of CBC. Over the observation period, two typical characteristics are recognized in plume temperatures measured with GKs: (1) the amplitudes of temperature anomalies decrease with increasing height above the top of CBC; (2) maximum temperature anomalies on the upper thermistors occurred periodically and nearly simultaneously across the array about every 6 hours. Conversely, maximum temperature anomalies on the lower thermistors occurred periodically every 12 hours, indicating that the location of the plume discharged from CBC was forcibly moved by the change in direction of tidally modulated current flow. The heat flux from CBC was estimated from temperatures measured by GKs based on a model of buoyant hydrothermal fluid rising in a stable, stratified density environment. The estimated heat flux from CBC gradually decreases from about 86 to 55 MW over the ~7 months of measurement, with a mean rate of decrease of 0.17 MW d-1. Since the black smoker effluent temperature measured with Hobo was almost stable over the measurement period, a plausible cause of the decrease is a reduction in the volume of hydrothermal fluid provided to the CBC (in which case the estimated mean rate of decrease in volume flux of CBC is 8.9 m3 d-1). Estimated heat flux, temperature anomalies observed by Hobo, and diffuse flow and subbottom temperature anomalies recorded by other long-term monitoring instruments before, during, and after ODP Leg 158 indicate that the drilling probably affected the fluid flow pattern within the mound but had little effect on the total heat flux from CBC.