Gracias Nuno

No Thumbnail Available
Last Name
Gracias
First Name
Nuno
ORCID

Search Results

Now showing 1 - 4 of 4
  • Article
    Globally aligned photomosaic of the Lucky Strike hydrothermal vent field (Mid-Atlantic Ridge, 37°18.5′N) : release of georeferenced data, mosaic construction, and viewing software
    (American Geophysical Union, 2008-12-05) Escartin, Javier E. ; Garcia, Rafael ; Delaunoy, O. ; Ferrer, J. ; Gracias, Nuno ; Elibol, A. ; Cufi, X. ; Neumann, L. ; Fornari, Daniel J. ; Humphris, Susan E. ; Renard, J.
    We present a georeferenced photomosaic of the Lucky Strike hydrothermal vent field (Mid-Atlantic Ridge, 37°18′N). The photomosaic was generated from digital photographs acquired using the ARGO II seafloor imaging system during the 1996 LUSTRE cruise, which surveyed a ∼1 km2 zone and provided a coverage of ∼20% of the seafloor. The photomosaic has a pixel resolution of 15 mm and encloses the areas with known active hydrothermal venting. The final mosaic is generated after an optimization that includes the automatic detection of the same benthic features across different images (feature-matching), followed by a global alignment of images based on the vehicle navigation. We also provide software to construct mosaics from large sets of images for which georeferencing information exists (location, attitude, and altitude per image), to visualize them, and to extract data. Georeferencing information can be provided by the raw navigation data (collected during the survey) or result from the optimization obtained from image matching. Mosaics based solely on navigation can be readily generated by any user but the optimization and global alignment of the mosaic requires a case-by-case approach for which no universally software is available. The Lucky Strike photomosaics (optimized and navigated-only) are publicly available through the Marine Geoscience Data System (MGDS, http://www.marine-geo.org). The mosaic-generating and viewing software is available through the Computer Vision and Robotics Group Web page at the University of Girona (http://eia.udg.es/∼rafa/mosaicviewer.html).
  • Preprint
    Hydrothermal activity along the slow-spreading Lucky Strike ridge segment (Mid-Atlantic Ridge) : distribution, heatflux, and geological controls
    ( 2015-09) Escartin, Javier E. ; Barreyre, Thibaut ; Cannat, Mathilde ; Garcia, Rafael ; Gracias, Nuno ; Deschamps, Anne ; Salocchi, Aura ; Sarradin, Pierre-Marie ; Ballu, Valerie
    We have reviewed available visual information from the seafloor, and recently acquired microbathymetry for several traverses across the Lucky Strike segment, to evaluate the distribution of hydrothermal activity. We have identified a new on-axis site with diffuse flow, Ewan, and anactive vent structure ~1.2 km from the axis, Capelinhos. These sites are minor relative to the Main field, and our total heatflux estimate for all active sites (200-1200 MW) is only slightly higher than previously published estimates. We also identify fossil sites W of the main Lucky Strike field. A circular feature ~200 m in diameter located on the flanks of a rifted off-axis central volcano, is likely a large and inactive hydrothermal edifice, named Grunnus. We find no indicator of focused hydrothermal activity elsewhere along the segment, suggesting that the enhanced melt supply and the associated melt lenses, required to form central volcanoes, also sustain hydrothermal circulation to form and maintain large and long-lived hydrothermal fields. Hydrothermal discharge to the seafloor occurs along fault traces, suggesting focusing of hydrothermal circulation in the shallow crust along permeable fault zones.
  • Article
    Quantifying diffuse and discrete venting at the Tour Eiffel vent site, Lucky Strike hydrothermal field
    (American Geophysical Union, 2012-04-19) Mittelstaedt, Eric ; Escartin, Javier E. ; Gracias, Nuno ; Olive, Jean-Arthur L. ; Barreyre, Thibaut ; Davaille, Anne ; Cannat, Mathilde ; Garcia, Rafael
    The relative heat carried by diffuse versus discrete venting of hydrothermal fluids at mid-ocean ridges is poorly constrained and likely varies among vent sites. Estimates of the proportion of heat carried by diffuse flow range from 0% to 100% of the total axial heat flux. Here, we present an approach that integrates imagery, video, and temperature measurements to accurately estimate this partitioning at a single vent site, Tour Eiffel in the Lucky Strike hydrothermal field along the Mid-Atlantic Ridge. Fluid temperatures, photographic mosaics of the vent site, and video sequences of fluid flow were acquired during the Bathyluck'09 cruise (Fall, 2009) and the Momarsat'10 cruise (Summer, 2010) to the Lucky Strike hydrothermal field by the ROV Victor6000 aboard the French research vessel the “Pourquoi Pas”? (IFREMER, France). We use two optical methods to calculate the velocities of imaged hydrothermal fluids: (1) for diffuse venting, Diffuse Flow Velocimetry tracks the displacement of refractive index anomalies through time, and (2) for discrete jets, Particle Image Velocimetry tracks eddies by cross-correlation of pixel intensities between subsequent images. To circumvent video blurring associated with rapid velocities at vent orifices, exit velocities at discrete vents are calculated from the best fit of the observed velocity field to a model of a steady state turbulent plume where we vary the model vent radius and fluid exit velocity. Our results yield vertical velocities of diffuse effluent between 0.9 cm s−1 and 11.1 cm s−1 for fluid temperatures between 3°C and 33.5°C above that of ambient seawater, and exit velocities of discrete jets between 22 cm s−1 and 119 cm s−1 for fluid temperatures between 200°C and 301°C above ambient seawater. Using the calculated fluid velocities, temperature measurements, and photo mosaics of the actively venting areas, we calculate a heat flux due to diffuse venting from thin fractures of 3.15 ± 2.22 MW, discrete venting of 1.07 ± 0.66 MW, and, by incorporating previous estimates of diffuse heat flux density from Tour Eiffel, diffuse flux from the main sulfide mound of ∼15.6 MW. We estimate that the total integrated heat flux from the Tour Eiffel site is 19.82 ± 2.88 MW and that the ratio of diffuse to discrete heat flux is ∼18. We discuss the implication of these results for the characterization of different vent sites within Lucky Strike and in the context of a compilation of all available measurements of the ratio of diffuse to discrete heat flux.
  • Article
    The Kallisti Limnes, carbon dioxide-accumulating subsea pools
    (Nature Publishing Group, 2015-07-16) Camilli, Richard ; Nomikou, Paraskevi ; Escartin, Javier E. ; Ridao, Pere ; Mallios, Angelos ; Kilias, Stephanos P. ; Argyraki, Ariadne ; Andreani, Muriel ; Ballu, Valerie ; Campos, Ricard ; Deplus, Christine ; Gabsi, Taoufic ; Garcia, Rafael ; Gracias, Nuno ; Hurtos, Natalia ; Magi, Lluis ; Mevel, Catherine ; Moreira, Manuel ; Palomeras, Narcis ; Pot, Olivier ; Ribas, David ; Ruzie, Lorraine ; Sakellariou, Dimitris
    Natural CO2 releases from shallow marine hydrothermal vents are assumed to mix into the water column, and not accumulate into stratified seafloor pools. We present newly discovered shallow subsea pools located within the Santorini volcanic caldera of the Southern Aegean Sea, Greece, that accumulate CO2 emissions from geologic reservoirs. This type of hydrothermal seafloor pool, containing highly concentrated CO2, provides direct evidence of shallow benthic CO2 accumulations originating from sub-seafloor releases. Samples taken from within these acidic pools are devoid of calcifying organisms, and channel structures among the pools indicate gravity driven flow, suggesting that seafloor release of CO2 at this site may preferentially impact benthic ecosystems. These naturally occurring seafloor pools may provide a diagnostic indicator of incipient volcanic activity and can serve as an analog for studying CO2 leakage and benthic accumulations from subsea carbon capture and storage sites.