Voltage scans from a prototype hollow core fiber isotope ratio laser spectrometer
Voltage scans from a prototype hollow core fiber isotope ratio laser spectrometer
dc.contributor.author | Wieman, Scott T. | |
dc.contributor.author | Kapit, Jason | |
dc.contributor.author | Guo, Weifu | |
dc.contributor.author | Michel, Anna P. M. | |
dc.date.accessioned | 2025-01-27T19:30:17Z | |
dc.date.available | 2025-01-27T19:30:17Z | |
dc.date.issued | 2024-08-22 | |
dc.description.abstract | This dataset consists of 900 one-second-long voltage acquisitions across 2000 detector channels from a prototype hollow core fiber isotope ratio laser spectrometer developed and operated at the Woods Hole Oceanographic Institution’s David Center for Ocean Innovation. Each acquisition covers a spectral range of ~2290.55 to 2299.15 cm-1. The operational conditions are 2.5 torr of pure CO2 in a 1m-long hollow core fiber with an inner diameter of 200 µm at room temperature (~20ºC). The laser was scanned across this spectral range at 50kHz and each one-second acquisition is the average of 50000 individual spectral scans within that one second. | |
dc.description.sponsorship | This work was supported by the Link Foundation Ocean Engineering and Innovation Fellowship, NSF OCE-2219885, the Woods Hole Oceanographic Institution (WHOI) Innovative Technology Award, the WHOI Investment in Science Fund, and the WHOI Ocean Venture Fund. | |
dc.identifier.citation | Wieman, S., Kapit , J., Guo, W., & Michel, A. (2025). Voltage scans from a prototype hollow core fiber isotope ratio laser spectrometer [Data set]. Woods Hole Oceanographic Institution. https://doi.org/10.26025/1912/71331 | |
dc.identifier.doi | 10.26025/1912/71331 | |
dc.identifier.uri | https://hdl.handle.net/1912/71331 | |
dc.publisher | Woods Hole Oceanographic Institution | |
dc.rights | Attribution 4.0 International | * |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | * |
dc.subject | Hollow core fiber | |
dc.subject | Isotope ratio laser spectrometer | |
dc.subject | Clumped isotopes | |
dc.subject | Carbon dioxide | |
dc.title | Voltage scans from a prototype hollow core fiber isotope ratio laser spectrometer | |
dc.type | Dataset | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | f55f0191-6f88-45dd-8677-8bccf929fc1b | |
relation.isAuthorOfPublication | 733a82be-91d3-476a-aad8-fe4020b3cab4 | |
relation.isAuthorOfPublication | 5b7ea08e-8249-4f4d-adce-81a7c2adf37e | |
relation.isAuthorOfPublication | bb157189-e61a-455d-9ca5-dbb77e8ab31b | |
relation.isAuthorOfPublication.latestForDiscovery | f55f0191-6f88-45dd-8677-8bccf929fc1b |