A robust calibration method for continental-scale soil water content measurements
Date
2018-05-24Author
Roberti, Joshua A.
Concept link
Ayres, Edward
Concept link
Loescher, Henry W.
Concept link
Tang, Jianwu
Concept link
Starr, Gregory
Concept link
Durden, David J.
Concept link
Smith, Derek E.
Concept link
de la Reguera, Elizabeth
Concept link
Morkeski, Kate
Concept link
McKlveen, Margot
Concept link
Benstead, Heidi
Concept link
SanClements, Michael D.
Concept link
Lee, Robert H.
Concept link
Gebremedhin, Gebremedhin
Concept link
Zulueta, Rommel C.
Concept link
Metadata
Show full item recordCitable URI
https://hdl.handle.net/1912/10524As published
https://doi.org/10.2136/vzj2017.10.0177DOI
10.2136/vzj2017.10.0177Abstract
Technological advances have allowed in situ monitoring of soil water content in an automated manner. These advances, along with an increase in large-scale networks monitoring soil water content, stress the need for a robust calibration framework that ensures that soil water content measurements are accurate and reliable. We have developed an approach to make consistent and comparable soil water content sensor calibrations across a continental-scale network in a production framework that incorporates a thorough accounting of uncertainties. More than 150 soil blocks of varying characteristics from 33 locations across the United States were used to generate soil-specific calibration coefficients for a capacitance sensor. We found that the manufacturer’s nominal calibration coefficients poorly fit the data for nearly all soil types. This resulted in negative (91% of samples) and positive (5% of samples) biases and a mean root mean square error (RMSE) of 0.123 cm3 cm−3 (1σ) relative to reference standard measurements. We derived soil-specific coefficients, and when used with the manufacturer’s nominal function, the biases were corrected and the mean RMSE dropped to ±0.017 cm3 cm−3 (±1σ). A logistic calibration function further reduced the mean RMSE to ±0.016 cm3 cm−3 (±1σ) and increased the range of soil moistures to which the calibration applied by 18% compared with the manufacturer’s function. However, the uncertainty of the reference standard was notable (±0.022 cm3 cm−3), and when propagated in quadrature with RMSE estimates, the combined uncertainty of the calibrated volumetric soil water content values increased to ±0.028 cm3 cm−3 regardless of the calibration function used.
Description
© Soil Science Society of America, 2018. This article is distributed under the terms of the Creative Commons Attribution License. The definitive version was published in Vadose Zone Journal 17 (2018): 170177, doi:10.2136/vzj2017.10.0177.
Collections
Suggested Citation
Vadose Zone Journal 17 (2018): 170177The following license files are associated with this item: